产品展示
网站首页 > 产品中心
|
赫斯曼交换机模块MM20-M2T1T1T1TAHH
产品编号:201312915128
产品价格:¥
产品描述:赫斯曼交换机模块MM20-M2T1T1T1TAHH,Port 1: 100BASE-FX, MM-SC; Port 2: 10/100BASE-TX, RJ45; Port 3: 10/100BASE-TX, RJ45; Port 4: 10/100BASE-TX, RJ45
|
|
产品介绍
Product description
Description |
Fast Ethernet media module for MICE Switches (MS...) |
Port type and quantity |
Port 1: 100BASE-FX, MM-SC; Port 2: 10/100BASE-TX, RJ45; Port 3: 10/100BASE-TX, RJ45; Port 4: 10/100BASE-TX, RJ45 |
Type |
MM20-M2T1T1T1TAHH |
Order No. |
MM20-M2T1T1T1TAHH |
Network size - length of cable
Twisted pair (TP) |
0 m ... 100 m |
Multimode fiber (MM) 50/125 µm |
0 - 5000 m, 8 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB Reserve, B = 800 MHz x km |
Multimode fiber (MM) 62.5/125 µm |
0 - 4000 m, 11 dB Link Budget at 1300 nm, A = 1 dB/km, 3 dB Reserve, B = 500 MHz x km |
Single mode fiber (SM) 9/125 µm |
- |
Single mode fiber (LH) 9/125 µm (long haul transceiver) |
- |
Power requirements
Operating voltage |
Power supply via the backplane of the MICE switch |
Power consumption |
2.3 W |
Ambient conditions
Operating temperature |
-40 ºC ... 70 ºC |
Storage/transport temperature |
-40 ºC ... 70 ºC |
Protective paint on PCB |
No |
Relative humidity (non-condensing) |
10 % ... 95 % |
Mechanical construction
Dimensions (W x H x D) |
38 mm x 134 mm x 118 mm |
Width |
38 mm |
Height |
134 mm |
Depth |
118 mm |
Mounting |
Backplane |
Weight |
n/a |
Protection class |
IP20 |
Mechanical stability
IEC 60068-2-27 shock |
15 g, 11 ms duration, 18 shocks |
IEC 60068-2-6 vibration |
1 mm, 2 Hz - 13,2 Hz, 90 min.; 0,7g, 13,2 Hz - 100 Hz, 90 min.; 3,5 mm, 3 Hz - 9 Hz, 10 Zyklen, 1 Oktave/min.; 1g, 9 Hz - 150 Hz, 10 Zyklen, 1 Oktave/min |
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) |
6 kV contact discharge, 8 kV air discharge |
EN 61000-4-3 electromagnetic field |
10 V/m (80 - 1000 MHz) |
EN 61000-4-4 fast transients (burst) |
2 kV power line, 1 kV data line |
EN 61000-4-5 surge voltage |
power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line |
EN 61000-4-6 conducted immunity |
3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) |
EMC emitted immunity
FCC CFR47 Part 15 |
FCC CFR47 Part 15 Class A |
EN 55022 |
EN 55022 Class A |
Approvals
Safety of industrial control equipment |
cUL 508 |
Hazardous locations |
ISA 12.12.01 Class 1 Div. 2 |
Scope of delivery and accessories
Scope of delivery |
Module, operating manual |
Accessories to order separately |
ML-MS2/MM labels |
|